Give website feedback. RPBA installations must meet all applicable Oregon Administrative Rules, 333-061-0070, Title 21, and Title 28, respectively. The platform will need to provide for 6-feet of vertical headroom. Copyright 2021 Hardin & Associates Consulting. Why Choose Us for Your Missouri City Backflow Prevention? Official Cross-Connection Control Program forms: Listed below are links to the official TCEQ Cross-Connection Control Program forms. Highline Water District (HWD) makes no representation regarding the abilities . Please follow the prompts andhave the project numberandyour scheduling PIN readily available. Fortunately, there are two inexpensive ways to solve this problem: As a homeowner, you may install and maintain your own irrigation system, but its still important to have a suitable backflow prevention assembly (BPA) in place and to be sure that it works properly. When jobs are completed through SwiftQuote, the work order is automatically submitted to participating jurisdictions through SwiftComplys compliance software. be isolated from the toilet bowl. If installed greater than 24", assemblies must be installed in a precast concreate vault that meets vault clearance standards as stated herein. ?H!H2@5H0 -.l>@Lu ut&30
c
g"`Q CL!s?gp\W80dpQ%0e8iF bS24IP s0 K
Interior and basement installations must provide drainage for the full rated flow of the relief-valve, or the supply piping must be equipped with an approved Flood Protection Shut Down Valve. A webcam or HD webcam - built-in, USB plug-in, or: An HD cam or HD camcorder with a video-capture card, Virtual camera software for use with broadcasting software like OBS or IP cameras. This is not a complete list of all certified testers in this state. All assemblies 2 and smaller (Excludes fire service assemblies, see information under fire sprinkler services) must be installed no more than 24 below finished grade. endstream
endobj
752 0 obj
<. 16. Certification required at final inspection. An approved rigidly mounted ladder, with an extension which extends 3 above the vault lid (Oldcastle Infrastructure Pull-Up Extension, Bilco LU-1 or equivalent) is required if the vault or chamber is 4 or greater in depth. Drawings must show property lines, building setbacks, identify street frontage, water main, service location and proposed backflow assembly type and location. BACKFLOW PREVENTION ASSEMBLY TEST REPORT. For horizontal installations, and for assemblies which are not approved for vertical up installation, the riser must be equipped with a single 90-degree elbow and the assembly is to be no more than the pipe diameter in inches beyond the centerline (or outlet side of the) elbow to accommodate horizontal installations, excepting only the addition of a wye-strainer, flood control shut off valve or other, necessary appurtenance. Planning, outreach and education, strategic, and technology projects. Upon installation of the Backflow Prevention device, please provide the following: a. This can be caused by backsiphonage or backpressure. Completing this course also provides continuing education credit for the following licenses: 32-hours of continuing education credits for licensed Backflow Prevention Assembly Testers, 12-hours of continuing education credits for licensed Water and Wastewater Operators, 12-hours of continuing education credits for licensed Landscape Irrigators (LI), 12-hours of continuing education credits for licensed Customer Service Inspectors (CSI), 12-hours of continuing education credits for licensed Water Treatment Specialist, 100-hours of training credit to an applicant for a Plumbing Inspectors license (through TSBPE). Backflow Test Status Pass Fail. Additionally, all piping for fire sprinkler system backflow assembly installations must be compliant with the local Fire code. Join to apply for the ENVIRONMENTAL INVESTIGATOR I/RC role at City of Houston. City of Houston: Lake Houston Dam Spillway Improvement Project: $7,500,000: Texas: . Touchpads or transmitters must be rigidly mounted and be serviceable. with respect to contracting with these or any testers. Enter the appropriate project number into the field and click the Submit button. Position Overview. 23828 30th Ave. S. Retrofit/Replacement backflow assembly installations must meet current State and City installation requirements. The Installer/Contractor will request a (Code418) inspection via phone by calling the Voice Permits (IVR) at 817-392-6370 or through the City of Fort Worth Development Services Department at 817-392-2222. The supply side of premises-isolation assemblies must be plumbed with potable water piping and fittings meeting current NSF/ANSI standards for lead content. A TCEQ-licensed Customer Service Inspector. assembly tested on an annual basis. Backflow occurs due to a sudden change in pressure or a break in the water main. Highline Water District Premises-isolation assemblies approved to be installed inside buildings or structures must be installed at the water supply riser/supply pipe. 205 0 obj
<>/Filter/FlateDecode/ID[]/Index[175 60]/Info 174 0 R/Length 134/Prev 362807/Root 176 0 R/Size 235/Type/XRef/W[1 3 1]>>stream
The following are requirements of the program: The customer agrees to abide by the rules and regulations regarding cross-connection control and backflow prevention outlined in the TCEQ's Customer Service Agreement in order to establish a connection with the City of Longview's potable water supply. CE hours are given for successful completion of TCEQ approved training courses. 234 0 obj
<>stream
797 0 obj
<>stream
See note below. testers. Strategically located halfway between the hub cities of Prince George and Terrace, Houston is home to the outdoor enthusiast.. With a population of 3200 people, there is always room on the riverbank, lake or the many walking and hiking trails in the area. The relief-valve must be located 12 above the top of the vault drain opening. Providers are invited to offer quotes for work and can message you directly to understand the job specifics. Adequate drainage: Backflow assemblies must not be installed in locations subject to flooding. This could be caused by pumps, boilers or storage tanks. 2. Potential contamination can make extra protection necessary for landscape irrigation systems, spas, swimming pools, solar water heating systems, or even a bucket of soapy water being filled by a garden hose. If the fire sprinkler service is fully metered (a meter approved by the Water Bureau for fire flow application and billing purposes) a Double Check Valve Assembly (DCVA) or Reduced Pressure Backflow Assembly (RPBA) may be installed depending on sprinkler system type. endstream
endobj
startxref
5. 15. A premises-isolation RPBA must be installed on all water service connections that pose a risk to health. Vaults must accommodate 6-feet of vertical headroom or have hinged double door opening frame and covers that accommodate the entire lay length of the assembly. Suite 100 A moisture-proof light fixture will be required if adequate lighting is not available. Third-Party CSI Inspectors: Ray Harlow: 832-349-4465 Terry Blanchard: 281-889-1443 Taylor: 936-647-5852. All services considered non-potable and do not pose a risk to health. a list of State Certified Assemblies approved to be installed inside buildings or structures must be located at the water riser/supply pipe. Backflow Prevention Assembly Types. Vaults and enclosures must not contain loose fill materials or debris of any kind. Yes No . Normally, water travels in one direction, from treatment plants, through water mains, then to each customers service connection. Backflow Prevention Information | City of Houston - Houston Public Works Backflow Prevention Information All certified backflow prevention assembly testers play an important role in protecting the City of Houston water customers. | Texas Veterans Portal Enter your license number (digits only) and scheduling PIN.
Some public water systems have licensed staff who perform the CSIs and then bill the customer for the inspection. Above ground enclosure installations may have clearances less than those mentioned for vault installations, provided they are equipped with removable panels, doors and tops that create clearances equal to or greater than those described herein. 7. Click Here for the requirements to register with the City of Houston as a backflow prevention assembly tester. Testing and repairing backflow prevention assemblies on fire suppression systems and lines. 4. Austin, 78744-1070 Assemblies must be readily accessible with adequate room for testing and maintenance: Assemblies 2 inches and smaller (excludes DCDAs, see next bullet) must maintain at least 4-inches clearance on all sides and at both ends, respectively. Have a High School Diploma or Equivalent Certificate, Pass an examination *Written exam must be taken at a TCEQ regional office or proctored computer-based testing facility as of May 2, 2016, Work at least two years in an approved area. Cross Connection Control Backflow Tester Company List. Where the worker was mixing the pesticide, the water pressure dropped, and the flow in the hose reversed. A RPBA must be installed on domestic water services to premises where shell buildings are constructed or renovated when occupancy is undetermined at the time of construction and/or renovation. Payable to: City of Pharr. On an outside building wall, at a height between 1 and 5 above the floor or finished grade and within 50 of the backflow assembly. Further, HWD does not assume or SwiftQuote is a free service for businesses. 4 clearance is required between the wall and the bypass, 24 clearance in front, 12 underneath, 3 at both ends and 36 vertically above the assembly body. 18. This list represents companies that have met the requirements and have submitted the proper documentation to register and . Where anti-freeze compounds, chemicals, gases, or any other additives are added to a fire sprinkler system, a Reduced Pressure Detector Assembly (RPDA) will be required. 751 0 obj
<>
endobj
@rvk`1i)S8::Al0T h``XS~W23TV9lU4v Backflow is the unintended flow of water from any domestic, industrial or institutional piping system into a drinking water supply system. We do this by using backflow prevention assemblies. Backflow assemblies installed on water services for fire use only; must be installed on private property at the property line (service connection/point-of-delivery as defined in the OAR) on the centerline of the city water service as it runs perpendicular from the R.O.W. The drain must never be less than 12 above the flood elevation of a water source, swale or any other catchment subject to overflow/flooding. For your convenience we provide Select the appropriate type of inspection and click the Submit button. The RPDA must be installed at the service connection/point-of-delivery to the premises as outlined herein and as defined by OAR Chapter 333-061-0020. All certified backflow prevention assembly testers play an important role in protecting the City of Houston water customers. Maintenance requirements include regular testing based on the type of device being used. An alternate assembly location may only be considered for retrofit applications and excludes new construction. 2. Fire systems that incorporate the use of storage tanks must be equipped with a RPDA and are required to be installed at the service connection/point-of-delivery to the premises as outlined herein. SwiftQuote stores your backflow service history and gives you instant access to your records. 7. water service customers who are advised to use their own judgment Registers must read in cubic feet. Backflow assemblies installed on water services that enter buildings with subgrade floors must conform to the following: Enter a building perpendicular to the centerline of the city water service and at an elevation as determined by the depth of the city water service at the R.O.W. 11. Put simply, a backflow preventer ensures water inside fire sprinklers, irrigation systems, and other water-based . The simplest method to prevent backflow is to have your backflow assembly tested on an annual basis. They identify locations where the risk of cross connection is high and ensure that the proper measures are taken to minimize that risk. Advance Pay Account holders may apply for the permit by fax. Check or Money Order ONLY. ABPA Certification:If interested in ABPA certification, please contact us for more information. Premises-isolation backflow assemblies must be those approved by University of Southern California Foundation for Cross-Connection Control and Hydraulic Research (USC) and the Oregon Health Authority (OHA). The Association of Contracting Plumbers of the City of New York, Inc. 535 8 th Ave, 17 th Floor New York, NY 10018 (212) 481-4580 {a$7@!!3ItPdQOx&V>K2[v:O2&Wi,a/%(&*KR&%lA2JE1"a&3"A DD1NuVU-EVV>}*fx+K!^UP|+Gpr,'H_Z9[9.rrU'A/{R/@8WW?.^Wy1iZ_'~A8UIyO32awJ{'3l}4{?jZF=P|l>}7WQu%XD"R'7s/[. No pressure testing is to be performed between a premises-isolation assembly and a Water Bureau valve in the right-of-way. For example, these and other businesses would be required to install high-grade backflow prevention assemblies and have them tested by a certified tester annually: Another aspect of an effective CCC program is the customer service inspection (CSI). 3907 South Industrial Drive Wires must not encumber the vault opening or ladder. When a RPBA is installed in an above ground enclosure, the enclosure drain must drain to finished grade and be able to discharge the full rated flow of the relief-valve. Emergency: 206-824-0375 The community of Houston is nestled in the beautiful Bulkley Valley amongst some of BC's finest outdoor recreational opportunities. If the available area between a building and the property line is adequate (determined by the Bureau), the vault, chamber, or enclosure for the type of backflow assembly required must be installed outside the confines of the building or structure. Assemblies 2 and smaller may have reduced clearances as approved by the Water Quality Inspector. 3) Annual registration fee of $100.00. We are available by phone, text, and email. Many public water systems also operate rigorous cross-connection control (CCC) programs of their own. SwiftQuote integrates with your municipality and uploads compliance records to the city on your behalf. Schedule single and recurring services via the SwiftQuote Web App through any device. In each of these cases, if backflow happens, your households water lines could be contaminated. A public water systems Cross-Connection Control Program is inspected during routine investigations made by our regional staff. Phone: 206-824-0375 most obvious case, a toilet flush cistern and its water supply must Backflow occurs for one of two reasons, either back pressure or The Cross-Connection Control Subcommittee advises us in this effort. susceptible to back-ups, proper backflow prevention shall be designed. Water service must not be activated and is subject to termination without notice until all backflow assembly installation related work has been completed. The following individuals are authorized to perform CSIs: OurOccupational Licensing Sectionlicenses Customer Service Inspectors and maintains a database of licensed Customer Service Inspectors.